Properties:
Related Categories |
Additional Standards,
Analytical Standards,
Analytical/Chromatography,
Proficiency Testing,
Water Pollution/Waste Water Organics,
|
packaging
|
ampule of 1 × 2 mL
|
mfr. no.
|
RTC, PEO-121-2B
|
concentration
|
in acetone
|
storage temp.
|
2-8°C
|
Description:
General description
This proficiency testing sample is produced in accordance with ISO/IEC 17043:2010. All information regarding the use of this material can be found in the reporting packet supplied for each sample.
Other Notes
Proficiency testing samples are presented as single blind. No values for the samples are released unti the testing period concludes. Values of analytes vary lot to lot.
Proficiency Testing Schedule (2017-2018)
Wastewater
WP17-1 January 18 - March 3, 2017
WP17-2 March 29 - May 12, 2017
WP17-3A May 17 - June 30, 2017
WP17-3B July 12 - August 25, 2017
WP17-4 September 27 - November 10, 2017
WP17-5 November 22 - January 5, 2018
WP18-1 January 17 - March 2, 2018
WP18-2 March 28 - May 11, 2018
WP18-3A May 16 - June 29, 2018
WP18-3B July 11 - August 24, 2018
WP18-4 September 26 - November 9, 2018
WP18-5 November 21 - January 4, 2019
Quick-Turn Study - (non-scheduled proficiency test that is available at any time)
Preparation Note
This PT sample is packaged as a 1.5 mL concentrate.
The solvent for This sample is acetone.
The PT sample is not preserved
Sample preparation
This ampule contains a concentrate of Base/Neutral compounds in acetone.
When prepared according to instructions, the concentration of each analyte will be less than 200 ug/L.
To prepare solution, add 1L of reagent water to a 2L separatory funnel.
Open ampule PE1171-2ML (be careful to avoid cuts on glass) and transfer exactly 1.0mL of the concentrate to the separatory funnel.
Mix well.
The sample is now ready for analysis.
For calculations, assume initial sample volume was 1000 mL.
Matrix Modifier
MMW-001 is intended to modify the products to simulate a waste water sample.
The final dilution will replace the use of DI (Reagent Grade) water for the prepartion of the appropriate CRM/QC sample.
The sample will add turbidity and TSS to the final volume. These do not affect the properties of the analytes of interest in the final sample if prepared according to instructions.
Note filtration may be necessary as required by your method.
To use the matrix modifier simply mix Waste Water Matrix Modifier as specified in the MMW-001 instructions. Use this solution in place of the reagent grade water in the instructions above.
Safety:
Symbol
GHS02, GHS07
Hazard statements
H225-H319-H336
Precautionary statements
P210-P280-P304 + P340 + P312-P305 + P351 + P338-P337 + P313-P403 + P235
Supplemental Hazard Statements
Repeated exposure may cause skin dryness or cracking.
RIDADR
UN1090 - class 3 - PG 2 - Acetone, solution