当前位置 : NEB >>> NEB/Luna® Probe One-Step RT-qPCR 4X Mix with UDG/200 reactions/M3019S
NEB/Luna® Probe One-Step RT-qPCR 4X Mix with UDG/200 reactions/M3019S
  • NEB/Luna® Probe One-Step RT-qPCR 4X Mix with UDG/200 reactions/M3019S

NEB/Luna® Probe One-Step RT-qPCR 4X Mix with UDG/200 reactions/M3019S

价格: 试用 市场价: 0.00

货号: M3019S
品牌: NEB
规格
数量
库存(0)
特别 提示
代购产品:无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
资深产品顾问
咨询顾问

全国免费服务热线

4000-520-616


  • 自营商城 一站式服务
  • 厂家直采 剔除溢价
  • 品质甄选 正品保证
  • 严控流程 只做188精品
  • 极速物流 如约送货
  • 详情
  • 使用说明
  • 常见问题
    • The Luna Probe One-Step RT-qPCR 4X Mix with UDG is designed for real-time detection of target RNA sequences using hydrolysis probes. In a single tube, RNA is first converted to cDNA by a reverse transcriptase, then a DNA-dependent DNA polymerase amplifies the cDNA, enabling quantitation via real time or quantitative PCR (qPCR). Probe-based qPCR/RT-qPCR monitors an increase in fluorescence upon 5′ to 3′ exonuclease cleavage of a quenched, target-specific probe to measure DNA amplification at each cycle of a PCR. At a point where the fluorescence signal is confidently detected over the background fluorescence, a quantification cycle or Cq value can be determined. Cq values can be used to evaluate relative target abundance between two or more samples.

      Due to the one-step RT-qPCR workflow and probe-based detection chemistry, a comparison can be made to the Luna Probe One-Step RT-qPCR Kit (NEB #E3006).

      Figure 1: A new product choice for one-step RT-qPCR assays
      The Luna Probe One-Step RT-qPCR Mix with UDG is supplied at a 4X concentration and enables higher amounts of sample input, which is relevant for applications where RNA present in low abundance is of interest, such as pathogen detection. Performance in multiplexing applications has been optimized, with sensitive, linear detection achieved for up to 5 targets across a range of inputs. The mix consolidates the necessary components for one-step RT-qPCR into a single tube, including Luna WarmStart RT, Hot Start Taq DNA Polymerase, dNTPs, and Murine RNase Inhibitor in an optimized buffer. Combining Hot Start Taq DNA Polymerase with a novel, WarmStart-activated reverse transcriptase allows for dual control of enzyme activity via reversible, aptamer-based inhibition. This temperature-dependent activation helps to prevent undesirable non-specific priming and extension prior to thermocycling, providing added security for setting up reactions at room temperature. The engineered Luna WarmStart RT also possesses higher thermostability than many other RTs, allowing an optimal reaction temperature of 55°C. Additionally, the mix is formulated with a unique passive reference dye that is compatible across a variety of instrument platforms, including those that require a high or low ROX reference signal.
      Figure 2:Robust amplification and detection of different viral RNA with Luna Probe One-Step RT-qPCR 4X Mix with UDG
      RT-qPCR targeting SARS-CoV-2 (N1 target) and H. influenza H1N1 (HA target) was performed using the Luna Probe One-Step RT-qPCR Mix with UDG. Performance in 20 μl reactions was evaluated in two real-time instruments over a 5-log range of (A) 10–100,000 copies Synthetic SARS-CoV-2 RNA Control 2 (Twist Biosciences, SKU: 102024) diluted in 10 ng of Jurkat total RNA (BioChain, #R1255815-50) and (B) 12.4–124,000 copies Influenza A (H1N1) RNA (ATCC®VR-95DQ™) diluted in 10 ng Jurkat total RNA. Sensitive, linear performance can be observed in the amplification of both viral targets.
      Figure 3:Multiplex detection (5 targets) with the Luna Probe One-Step RT-qPCR 4X Mix with UDG
      Multiplex RT-qPCR was performed using the Luna Probe One-Step RT-qPCR 4X Mix with UDG over a 5-log range of Jurkat total RNA (100 ng to 10 pg) on a Bio-Rad CFX96 real-time instrument. Amplification standard curves and efficiencies for each of the 5 human targets are shown. Reactions (20 μl) included primers and probes at 200 nM each, and followed the product recommended cycling conditions. All five targets were detected linearly in the multiplex reactions with strong efficiency and R2 values.
      Figure 4:The Luna Probe One-Step RT-qPCR 4X Mix with UDG outperforms comparable products
      One-step RT-qPCR was tested on 8 RT-qPCR targets (indicated by color) varying in abundance, length, and %GC. Data was collected on multiple days by two users according to manufacturer’s recommendations using the Applied Biosystems™ QuantStudio™ 6 real-time PCR system. Results were evaluated for efficiency, low input detection and lack of non-template amplification (where ΔCq = average Cq of non-template control – average Cq of lowest input). In addition, consistency, reproducibility and overall curve quality were assessed based on metrics described previously (Quality Score). Although both products performed reasonably well, NEB’s Luna Probe RT-qPCR 4X Mix with UDG outperformed the TaqPath 1-Step RT-qPCR Master Mix, CG, as evidenced by the higher number of experiments whose results fell in the green box.
      The sensitivity of RT-qPCR makes it important to minimize DNA contamination wherever possible. The inclusion of dUTP and thermolabile UDG prevents carryover contamination, where unintended product of a previous amplification can serve as the substrate of a subsequent reaction. The thermolabile UDG is completely inactivated at temperatures above 50°C, thereby having no effect on qPCR performance.
      Figure 5:Evaluation of RT-qPCR carryover prevention
      To evaluate the capacity of carryover product digestion, a uracil-containing RT-qPCR product was generated using the Luna One-Step Probe RT-qPCR kit. Approximately 105 copies of the uracil-containing product were used as template for subsequent qPCR reactions using three different RT-qPCR master mixes (all containing UDG). Following manufacturer’s recommended protocols, incubation at 25˚C at the start of the 2nd reaction enables UDG to degrade the dU-containing input, reducing its ability to contribute to a (false) positive signal. The ΔCq value is the cycle difference between carryover treatment and no carryover treatment of the same input. Larger ΔCq values indicate more efficient carryover product digestion. After decontamination using the Luna mix, full product digestion was observed in one sample and a large ΔCq was observed in the second. Note that the amount of DNA present in true contamination events is difficult to assess/predict.
      A non-fluorescent visible blue tracking dye is included to assist in pipetting into clear vessels. The tracking dye does not overlap spectrally with fluorophores commonly used in qPCR and does not interfere with real-time detection.

      The Luna Probe One-Step RT-qPCR Master Mix with UDG contains an inert blue tracking dye to eliminate pipetting errors.
      This product is related to the following categories:
      Luna® qPCR & RT-qPCR Products
      This product can be used in the following applications:
      qPCR & RT-qPCR,
      RT-qPCR, RT-PCR and cDNA Synthesis
    售后保障
    蚂蚁淘生物188,秉承蚂蚁淘一贯的严谨态度,由蚂蚁淘公司专业人员负责品控、采购、物流、销售、售后,保障正品优质。以“快速好省,为科研提供好产品、好价格”为理念,直接链接原厂家,从全国各地原制造商严格挑选188款科研精品,剔除品牌溢价,188生物新电商,把好的产品带给科研!  力求给你最优质的商品。
  • Q:生物188产品正品保障吗?
    A:生物188质量把控人员具有十年的从业经验,在业界享有良好的口碑;自营商城,直接从厂家采购, 自己的团队负责国际物流和清关,中间没有第三方,所有流程严格把控,100%保证正品,假一罚十。

    Q:下单后可以修改订单吗?
    A:下单后的商品付款之前可以修改;订单付款成功,需要联系我们客服进行修改;客服电话:4000-520-616

    Q:可以开发票吗?
    A:本网站所售商品都是正规清关,均开具16%正规发票,发票金额含配送费金额,另有说明的除外。

    Q:商品几天可以发货?
    A:生物188商品,全部现货销售,付款后即可发货,一般一周内送达!

    Q:如何联系商家?
    A:有任何问题够可以电话咨询我们,全国24小时免费服务热线:4000-520-616 或联系我们的在线客服QQ:1570468124

    Q:收到的商品少了/发错了怎么办?
    A:同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是 部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。

    Q:退换货/维修需要多长时间?
    A:一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、 数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。

何为188

极简而严谨,我们仅销售188款生物医学科研用品,款款都是爆款;因为少所以聚焦,聚焦甄选每一款产品,聚焦服务每一位客户!

关注我们 :

点击QQ联系我们
生物188微信

关注188微信公众号

获取最新优惠活动通知
  • 品质甄选,正品保证

  • 自营电商,厂家直采

  • 极简主义,188精品