当前位置 : NEB >>> NEB/NEBNext® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4)/384 reactions/E7878L
NEB/NEBNext® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4)/384 reactions/E7878L
  • NEB/NEBNext® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4)/384 reactions/E7878L

NEB/NEBNext® Multiplex Oligos for Illumina® (Unique Dual Index UMI Adaptors DNA Set 4)/384 reactions/E7878L

价格: 试用 市场价: 0.00

货号: E7878L
品牌: NEB
规格
数量
库存(0)
特别 提示
代购产品:无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
资深产品顾问
咨询顾问

全国免费服务热线

4000-520-616


  • 自营商城 一站式服务
  • 厂家直采 剔除溢价
  • 品质甄选 正品保证
  • 严控流程 只做188精品
  • 极速物流 如约送货
  • 详情
  • 使用说明
  • 常见问题
    • NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 4) are built for more streamlined and informative NGS multiplexing, tracking the sequencing reaction at the individual molecule level and enabling bioinformatic removal of misassigned reads for optimal accuracy. These index adaptors contain a pair of unique dual indices (i5 and i7) and one UMI sequence, making the resulting library multiplex-ready, with or without PCR. This set includes 96 unique dual index UMI adaptors, packaged in a single-use 96-well plate with a pierceable foil seal. The universal primer mix is supplied in a separate vial.The NEBNext line of Multiplex Oligos can be used with NEBNext sample prep products or other standard Illumina-compatible library preparation protocols. In addition to this set, there are three other sets of NEBNext Unique Dual Index UMI Adaptors for DNA (NEB #E7395,#E7874,#E7876) for multiplexing of up to 384 samples; additional index adaptors with UMIs are available for RNA-seq (NEB #E7416). For multiplexing without UMIs, NEBNext offers several options for added flexibility, including unique dual index primers (NEB #6440, NEB #6442, NEB #E6444, NEB #E6446, and NEB #E6448), dual index primers (NEB #E7600andNEB #E7780), and single primer sets (in 12- and 96-index formats;NEB #E7335,NEB #E7500,NEB #E7710,NEB #E7730,NEB #E6609), as well as an option compatible with EM-seq™ and bisulfite sequencing (NEB #E7140).For larger volume requirements, customized and/or bulk packaging is available through our Customized Solutions Team. Please contact us atcustom@neb.com.NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 3) enable both PCR-free and amplification-based workflows for DNA library preparation. Refer to the below diagram for the differences between the two options.
      Figure 1. NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 4) WorkflowUMI Worflows
      Figure 2. NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 4) allow higher ligation efficiency.UMI Sets
      A. Libraries were prepared with 100, 250, and 500 ng inputs of human cell line NA19240 genomic DNA (Coriell Institute for Biomedical Research) and unique dual index adaptors from different suppliers using the NEBNext Ultra™ II FS DNA Library Prep Kit (NEB #E7805) without PCR amplification. The adaptors used were NEBNext Unique Dual Index UMI Adaptrs, xGen® Dual Index UMI Adapters (IDT®) and Nextflex® Unique Dual index Barcodes 1-96 (Bioo Scientific®). Two rounds of SPRIselect bead-based cleanup steps were performed post-ligation, and libraries were quantified by qPCR (NEBNext Library Quant Kit, NEB #E7630).
      B. 90 libraries were prepared with 100 ng NA19240 genomic DNA using the Ultra II FS DNA Library Prep Kit without PCR amplification in a 96-well plate. For the 90 libraries, 30 different adaptors each from NEB, IDT, and Bioo were used for ligation. Libraries were cleaned up and quantitated by qPCR.
      Figure 3. NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 4) allow more-sensitive, low-frequency variant detection.UMI Sets
      AcroMetrix®Oncology Hotspot Control DNA (Thermo Scientific®) was used as a mutation DNA source (> 500 mutations with 5-35% allele frequency) and mixed with NA19240 genomic DNA at various ratios to generate a range of allele frequencies (5%-35%, 2.5%-17.5% and 1%-7%). Libraries were constructed using NEBNext Ultra II DNA Library Prep Kit (NEB #E7645) with NEBNext Unique Dual Index UMI Adaptors, and multiplex hybrid capture was performed on all samples using a customized panel for 152 genes from Twist Bioscience®. Libraries were sequenced on a NovaSeq®6000 (PE140), and reads were downsampled to 110 Million (Seqtk Sample) and mapped to GRCh38 with BWA MEM (0.7.17). Mapped reads were analyzed by MarkDuplicates (Picard 2.20.6) without utilizing UMI information or by building UMI consensus sequences (Fgbio 0.8.1). The final BAM files were used to call somatic variants with Strelka2 (2.9.10).
      A. The number of total and correct SNV calls increased when using UMI information for duplicate removal and consensus sequence-based error correction.
      B. The sensitivity of variant detection was improved with UMI consensus calling. The lower the allele frequency, the more benefit provided by UMI information in SNV detection.
      Figure 4. NEBNext Unique Dual Index UMI Adaptors DNA Set 4 provides consistent library yields
      96 Libraries were each prepared with 50 ng input of human cell line NA19240 genomic DNA (Coriell Institute for Biomedical Research) and the NEBNext Unique Dual Index UMI Adaptors DNA Set 3 using the NEBNext Ultra II FS PCR-free DNA Library Prep Kit (NEB #E6177) in a 96 well plate. Library cleanup was followed by qPCR quantification. Library concentrations ranged from 7.3 nM to 3.4 nM with a 2.1-fold difference across all 96 adaptors.
      Figure 5. NEBNext Unique Dual Index UMI Adaptors DNA Set 4 provides consistent clustering efficiency on MiSeq® and NovaSeq 6000E7878
      Fig Desc: 96 libraries prepared using the NEBnext Unique Dual Index UMI Adaptors DNA Set 2 and the NEBNext Ultra II FS PCR-free DNA Library Prep Kit (NEB #E6177) were pooled at equimolar concentrations and sequenced on the Illumina MiSeq and NovaSeq 6000 instruments. The total number of reads from all libraries were summed, and the fraction of the total reads contributed by each library was determined (expected faction per library = 1.04%). All 96 libraries clustered efficiently and were represented at approximately the expected frequency on both platforms.
      Figure 6. All libraries prepared with 384 NEBNext Unique Dual Index UMI Adaptors cluster evenly on the Illumina NovaSeq 6000NEBNext
      384 libraries prepared using the NEBNext Unique Dual Index UMI Adaptors DNA Sets 1-4 and the NEBNext Ultra II FS PCR-free Library Prep Kit (NEB #E6177) were pooled at equimolar concentrations and sequenced on the Illumina NovaSeq 6000 instrument. The total number of reads from all libraries was summed, and the fraction of the total reads contributed by each library was determined (expected fraction per library = 0.26%). All 384 libraries clustered efficiently and were represented at approximately the expected frequency.
      This product is related to the following categories:
      NEBNext® Multiplex Oligos (Adaptors & Primers),
      Next Generation Sequencing Library Preparation
    售后保障
    蚂蚁淘生物188,秉承蚂蚁淘一贯的严谨态度,由蚂蚁淘公司专业人员负责品控、采购、物流、销售、售后,保障正品优质。以“快速好省,为科研提供好产品、好价格”为理念,直接链接原厂家,从全国各地原制造商严格挑选188款科研精品,剔除品牌溢价,188生物新电商,把好的产品带给科研!  力求给你最优质的商品。
  • Q:生物188产品正品保障吗?
    A:生物188质量把控人员具有十年的从业经验,在业界享有良好的口碑;自营商城,直接从厂家采购, 自己的团队负责国际物流和清关,中间没有第三方,所有流程严格把控,100%保证正品,假一罚十。

    Q:下单后可以修改订单吗?
    A:下单后的商品付款之前可以修改;订单付款成功,需要联系我们客服进行修改;客服电话:4000-520-616

    Q:可以开发票吗?
    A:本网站所售商品都是正规清关,均开具16%正规发票,发票金额含配送费金额,另有说明的除外。

    Q:商品几天可以发货?
    A:生物188商品,全部现货销售,付款后即可发货,一般一周内送达!

    Q:如何联系商家?
    A:有任何问题够可以电话咨询我们,全国24小时免费服务热线:4000-520-616 或联系我们的在线客服QQ:1570468124

    Q:收到的商品少了/发错了怎么办?
    A:同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是 部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。

    Q:退换货/维修需要多长时间?
    A:一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、 数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。

何为188

极简而严谨,我们仅销售188款生物医学科研用品,款款都是爆款;因为少所以聚焦,聚焦甄选每一款产品,聚焦服务每一位客户!

关注我们 :

点击QQ联系我们
生物188微信

关注188微信公众号

获取最新优惠活动通知
  • 品质甄选,正品保证

  • 自营电商,厂家直采

  • 极简主义,188精品