当前位置 : NEB >>> NEB/NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat)/6 reactions/E7750S
NEB/NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat)/6 reactions/E7750S
  • NEB/NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat)/6 reactions/E7750S

NEB/NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat)/6 reactions/E7750S

价格: 试用 市场价: 0.00

货号: E7750S
品牌: NEB
规格
数量
库存(0)
特别 提示
代购产品:无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
资深产品顾问
咨询顾问

全国免费服务热线

4000-520-616


  • 自营商城 一站式服务
  • 厂家直采 剔除溢价
  • 品质甄选 正品保证
  • 严控流程 只做188精品
  • 极速物流 如约送货
  • 详情
  • 使用说明
  • 常见问题
    • The great majority of RNA in blood samples is comprised of cytoplasmic and mitochondrial ribosomal RNAs (rRNA) and globin mRNA. These highly abundant RNA species can conceal the biological significance of less abundant transcripts, and so their efficient and specific removal is desirable.

      The NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat) employs the NEBNext RNase H-based RNA depletion workflow to deplete adult, embryonic and fetal globin mRNA (HBA1/2, HBB, HBD, HBM, HBG1/2, HBE1, HBQ1 and HBZ), cytoplasmic rRNA (5S, 5.8S, 18S, 28S, ITS and ETS) and mitochondrial rRNA (12S and 16S).

      The kit is effective with human, mouse and rat total RNA preparations, both intact and degraded. The resulting depleted RNA is suitable for RNA-seq, random-primed cDNA synthesis, or other downstream RNA analysis.

      This kit can also be used following poly(A) mRNA enrichment (e.g., using the NEBNext poly(A) mRNA Magnetic Isolation Module NEB #E7490), so that the final depleted RNA contains only mRNA of interest and no non-coding RNA.The kit is also available with RNAClean® beads.Features

      • Efficient, specific depletion of rRNA and globin mRNA (adult, fetal and embryonic)
      • Suitable for low-quality or high-quality RNA
      • Compatible with a broad range of input amounts: 10 ng - 1 μg
      • Optional integration with poly(A) mRNA isolation workflows for removal of globin RNAs, rRNAs, and noncoding RNAs
      • Fast workflow: 2 hours, with less than 10 minutes hands-on time

      For use with NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1) (NEB #E7416), refer to the Protocols tab for UMI Adaptors-specific guidance.

      Figure 1. Depletion of globin mRNA and ribosomal RNA enriches for RNAs of interest across species
      Human, mouse and rat whole blood total RNA (1 µg) was depleted of rRNA alone, or rRNA and globin mRNA transcripts, using the NEBNext Globin & rRNA Depletion Kit. RNA-seq libraries were prepared from untreated and depleted RNA using the NEBNext Ultra™ II RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). Reads were identified as rRNA or globin mRNA using mirabait (6 or more, 25-mers), and levels of rRNA and globin mRNA remaining were calculated by dividing matched reads by the total number of reads passing instrument quality filtering.
      Figure 2: Consistent Depletion Across Species and Across Inputs
      Human, mouse and rat whole blood total RNA (1 µg, 100 ng and 10 ng) was depleted of rRNA and globin mRNA using the NEBNext Globin & rRNA Depletion Kit or Globin-Zero® Gold rRNA Depletion Kit (Illumina®). RNA-seq libraries were prepared from untreated and depleted RNA using the NEBNext Ultra™ II RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). Reads were identified as ribosomal or globin using mirabait (6 or more, 25-mers), and levels of rRNA and globin mRNA remaining were calculated by dividing matched reads by the total number of reads passing instrument quality filtering. The data represents an average of 3 replicates and error bars indicate standard error. The NEBNext Globin Depletion Kit is superior at depleting rRNA across species, and at depleting over 99% of globin mRNA.
      Figure 3: Transcript expression correlation is maintained after depletion
      Human whole blood total RNA (1 µg) was depleted of rRNA and globin mRNA using the NEBNext Globin & rRNA Depletion Kit or Globin-Zero® Gold rRNA Depletion Kit (Illumina®). RNA-seq libraries were prepared from untreated and depleted RNA using the NEBNext Ultra™ II RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). GENCODE v27 transcript abundances were estimated using Salmon. TPM (Transcript Per Million mapped reads) of protein coding transcripts, and R2 values for the linear fit are shown.Correlation analysis of the transcripts indicates better transcript expression correlation between depleted and undepleted samples for the NEBNext Globin & rRNA Depletion Kit. Treatment does not alter the abundances of non-targeted transcripts.
      Figure 4: Transcript expression correlation is maintained across a range of input amounts
      Human whole blood total RNA (1 µg, 100 ng and 10 ng) was depleted of rRNA and globin mRNA using the NEBNext Globin & rRNA Depletion Kit. RNA-seq libraries were prepared using the NEBNext Ultra™ II RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). GENCODE v27 transcript abundances were estimated using Salmon. TPM (Transcript Per Million mapped reads) and R2 values for the linear fit are shown. Correlation analysis of the transcripts indicates consistent transcript expression regardless of input amount.
      This product is related to the following categories:
      RNA Depletion & mRNA Enrichment,
      RNA Library Prep for Illumina
      This product can be used in the following applications:
      RNA-seq,
      RNA Analysis
    售后保障
    蚂蚁淘生物188,秉承蚂蚁淘一贯的严谨态度,由蚂蚁淘公司专业人员负责品控、采购、物流、销售、售后,保障正品优质。以“快速好省,为科研提供好产品、好价格”为理念,直接链接原厂家,从全国各地原制造商严格挑选188款科研精品,剔除品牌溢价,188生物新电商,把好的产品带给科研!  力求给你最优质的商品。
  • Q:生物188产品正品保障吗?
    A:生物188质量把控人员具有十年的从业经验,在业界享有良好的口碑;自营商城,直接从厂家采购, 自己的团队负责国际物流和清关,中间没有第三方,所有流程严格把控,100%保证正品,假一罚十。

    Q:下单后可以修改订单吗?
    A:下单后的商品付款之前可以修改;订单付款成功,需要联系我们客服进行修改;客服电话:4000-520-616

    Q:可以开发票吗?
    A:本网站所售商品都是正规清关,均开具16%正规发票,发票金额含配送费金额,另有说明的除外。

    Q:商品几天可以发货?
    A:生物188商品,全部现货销售,付款后即可发货,一般一周内送达!

    Q:如何联系商家?
    A:有任何问题够可以电话咨询我们,全国24小时免费服务热线:4000-520-616 或联系我们的在线客服QQ:1570468124

    Q:收到的商品少了/发错了怎么办?
    A:同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是 部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。

    Q:退换货/维修需要多长时间?
    A:一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、 数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。

何为188

极简而严谨,我们仅销售188款生物医学科研用品,款款都是爆款;因为少所以聚焦,聚焦甄选每一款产品,聚焦服务每一位客户!

关注我们 :

点击QQ联系我们
生物188微信

关注188微信公众号

获取最新优惠活动通知
  • 品质甄选,正品保证

  • 自营电商,厂家直采

  • 极简主义,188精品