当前位置 : NEB >>> NEB/NEBNext FFPE DNA Repair v2 Module/96 reactions/E7360L
NEB/NEBNext FFPE DNA Repair v2 Module/96 reactions/E7360L
  • NEB/NEBNext FFPE DNA Repair v2 Module/96 reactions/E7360L

NEB/NEBNext FFPE DNA Repair v2 Module/96 reactions/E7360L

价格: 试用 市场价: 0.00

货号: E7360L
品牌: NEB
规格
数量
库存(0)
特别 提示
代购产品:无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
资深产品顾问
咨询顾问

全国免费服务热线

4000-520-616


  • 自营商城 一站式服务
  • 厂家直采 剔除溢价
  • 品质甄选 正品保证
  • 严控流程 只做188精品
  • 极速物流 如约送货
  • 详情
  • 使用说明
  • 常见问题
    • The NEBNext FFPE DNA Repair v2 Module contains enzymes and buffers that have been optimized to repair FFPE DNA in next generation sequencing workflows in a streamlined manner.The NEBNext FFPE DNA Repair v2 Module improves upon the performance of the original NEBNext FFPE DNA Repair Mix:

      • Higher repair efficiency with FFPE DNA
      • A more streamlined workflow for NGS library preparation
      • A more convenient reaction buffer containing all required buffer components for both efficient FFPE DNA repair and downstream end repair and dA-tailing.
      • No cleanup is required between repair and library prep, through the use of Thermolabile Proteinase K.

      Table 1: Types of FFPE DNA damage and their ability to be repaired by the NEBNext FFPE DNA Repair v2 Module

      FFPE DAMAGE TYPE REPAIRED BY THE FFPE DNA REPAIR v2 MODULE
      Deamination of cytosine to uracil Yes
      Nicks and gaps Yes
      Oxidized bases Yes
      Blocked 3´ ends Yes
      DNA fragmentation No
      DNA-protein crosslinks No
      Figure 1: Workflow demonstrating the use of the NEBNextFFPE DNA Repair v2 Module with the NEBNext Ultra™ II DNA Library Prep Kit for Illumina®
      Figure 2: The NEBNext FFPE DNA Repair v2 Module enables robust library preparation from a broad range of FFPE DNA sample qualities.
      Libraries were prepared with 25 ng of Covaris®acoustic-sheared FFPE DNA samples of different qualities and tissue sources. The NEBNext FFPE DNA Repair v2 Module was used, followed by NEBNext Ultra II DNA library preparation (NEB #E7645) with 9 PCR cycles. Libraries were quantified using the Agilent® HS D1000 TapeStation®. The NEBNext FFPE DNA Repair v2 Module improves the yield of FFPE libraries by varying degrees depending on the quality and damage types present in the input DNA. Error bars indicate the standard deviation of two replicates for each library sample.
      Figure 3: The NEBNext FFPE DNA Repair v2 Module enables robust library preparation from 5 to 250 ng of FFPE DNA input using both NEBNext hairpin and Unique Dual Index UMI Adaptors
      Libraries were prepared with 5, 50, or 250 ng of three different quality normal liver FFPE DNA samples comparing treatment with and without the NEBNext FFPE DNA Repair v2 Module. The NEBNext Ultra II DNA Library Preparation Kit (NEB #E7645) was used with (a) the NEBNext hairpin adaptor and 11, 8 and 6 PCR amplification cycles for 5, 50 and 250 ng inputs, respectively, and (b) the NEBNext Unique Dual Index UMI DNA Adaptors (NEB #E7395) and 11, 8 and 6 PCR cycles for 5, 50 and 250 ng inputs, respectively. All libraries were quantified using the Agilent HS D1000 Tapestation and the average yield of 2 libraries (5 and 50 ng) and 1 replicate (250 ng) was plotted. Error bars indicate standard deviation for the 5 and 50 ng library replicates. The NEBNext FFPE DNA Repair v2 Module is compatible with 5 to 250 ng inputs of FFPE DNA and different NEBNext adaptors.
      Figure 4: The NEBNext FFPE DNA Repair v2 Module improves library quality metrics including mapping rate, properly paired reads, and chimeric reads
      Libraries were prepared with 50 ng of three different quality normal liver FFPE DNA samples in triplicate, either untreated or treated with the NEBNext FFPE DNA Repair v2 Module before library preparation using the NEBNext Ultra II DNA Library Prep Kit (NEB #E7645). Libraries were sequenced on the Illumina NextSeq®500. Paired-end reads were downsampled to 1 million reads and mapped to the GRCh38 human reference (RefSeq 884148) using Bowtie2 (v2.3.2). Mapped reads were analyzed with MarkDuplicates (v1.56.0) and Picard SAM/BAM alignment summary metrics (v1.56.0). Treatment with the NEBNext FFPE DNA Repair v2 Module increases the mapping rate and decreases the level of non-properly paired and chimeric reads.
      Figure 5: The NEBNext FFPE DNA Repair v2 Module repairs abundant cytosine deamination artifacts present in FFPE DNA samples
      50 ng samples of two different normal liver FFPE DNAs (DIN 2.0 and DIN 1.8) were either untreated or treated in duplicate with the NEBNext FFPE DNA Repair v2 Module, followed by library preparation using the NEBNext Ultra II DNA Library Prep Kit (NEB #E7645). Libraries were sequenced on the Illumina NextSeq®500. Paired-end reads were downsampled to 1 million reads and mapped to the GRCh38 human reference (RefSeq 884148) using Bowtie2 (v2.3.2). Mapped reads were analyzed with MarkDuplicates (v1.56.0) and dCdT (CT) mutations were analyzed using Tasmanian (V0.1.3) according to the equation MAX(([C T] - [G A]) / ([NC]+[NG]), EXP(-10)). (a) The frequency of artifactual CT mutations was plotted as a function of read position (0 to 75 bp) in read 1 and read 2. The abundance and positional bias of these artifacts were reduced in two different FFPE DNA samples when treated with the NEBNext FFPE DNA Repair v2 Module. (b) Artifactual mutations identified in read 2 were quantified as an overall frequency. Two replicates for each condition are shown.
      Figure 6: The NEBNext FFPE DNA Repair v2 Module repairs oxidative damage in FFPE and non-FFPE DNA samples
      A. Libraries were prepared in duplicate with 25 ng of two different normal FFPE DNA samples of different qualities and tissue sources, comparing untreated to treated with the NEBNext FFPE DNA Repair v2 Module. Libraries were prepared using the NEBNext Ultra II DNA Library Prep Kit (NEB #E7645), sequenced on the Illumina NextSeq® 500, downsampled to 2 million reads, mapped to the GRCh38 human reference genome using Bowtie2 (v2.3.2). Mapped reads were analyzed by MarkDuplicates (v1.56.0) and Tasmanian (V0.1.3). The frequency of artifactual dGdT (GT) mutations in read 1 are shown for each library replicate. dGdT mutations were calculated according to the equation MAX(([G T] - [C A]) / ([NG]+[NC]), EXP(-10)).B. Libraries were prepared in duplicate using 100 ng of human genomic DNA Covaris-sheared in either water* or Tris-EDTA pH 8.0, the NEBNext FFPE DNA Repair v2 Module, and the NEBNext Ultra II DNA Library Prep Kit (NEB #E7645). Libraries were sequenced on the Illumina NextSeq 500, downsampled to 2 million reads and analyzed for GT mutation frequency as above. *Note: Shearing DNA in water is not recommended by the manufacturer (Covaris) but was used to generate a substrate containing oxidative damage.
      Figure 7: The NEBNext FFPE DNA Repair v2 Module improves library yield compared to treatment with UDG enzyme
      Libraries were prepared in duplicate using 50 ng FFPE DNA input from 4 different normal FFPE DNAs of different tissue sources and qualities (FFPE #1-3 with DIN 2.0 and FFPE #4 with DIN 6.7). Libraries were either untreated, treated with the NEBNext FFPE DNA Repair v2 Module, or treated with UDG enzyme (NEB #M0280) before preparing libraries with the NEBNext Ultra II DNA Library Preparation Kit for Illumina (NEB #E7645). While UDG enzyme can eliminate dU bases from input DNA, the NEBNext FFPE DNA Repair v2 Module can fully repair these damage sites and improve the final library yield (Figures 2, 3, 7) and metrics (Figure 4).
      Figure 8: The NEBNext FFPE DNA Repair v2 Module reduces false positives in somatic variant calling arising from cytosine deamination artifacts
      Libraries were prepared from 100 ng of four different FFPE DNA samples of varying qualities and tissue sources in duplicate using the NEBNext FFPE DNA Repair v2 Module or NEBNext FFPE DNA Repair Mix (NEB #M6630), the NEBNext Unique Dual Index UMI Adaptors (NEB #E7395), the NEBNext Ultra II DNA Library Prep Kit (NEB #E7645) and 10 PCR cycles. Libraries were captured using a custom cancer hotspot panel (Twist Bioscience®) and sequenced on the Illumina NextSeq 2000. All fastq files were downsampled to the same number of reads (2 X 18 million reads fresh frozen and 2 X 13 million for FFPE). Paired reads were trimmed with fastp (version 0.20.0) and mapped with BWA mem (0.7.17). Markduplicate was processed in picard (2.20.6) with UMI information. UMI information was processed in fgbio (0.8.1) to obtain consensus sequence reads. The final bam files with UMI-based consensus reads were used for somatic variant calling with strelka2 (2.9.10). Somatic variant calls are plotted according to substitution type for each condition. NEBNext FFPE DNA Repair v2 improves the efficiency of cytosine deamination repair (CT/GA) and effectively repairs oxidative damage (GT/CA).
      This product is related to the following categories:
      Next Generation Sequencing Library Preparation
    售后保障
    蚂蚁淘生物188,秉承蚂蚁淘一贯的严谨态度,由蚂蚁淘公司专业人员负责品控、采购、物流、销售、售后,保障正品优质。以“快速好省,为科研提供好产品、好价格”为理念,直接链接原厂家,从全国各地原制造商严格挑选188款科研精品,剔除品牌溢价,188生物新电商,把好的产品带给科研!  力求给你最优质的商品。
  • Q:生物188产品正品保障吗?
    A:生物188质量把控人员具有十年的从业经验,在业界享有良好的口碑;自营商城,直接从厂家采购, 自己的团队负责国际物流和清关,中间没有第三方,所有流程严格把控,100%保证正品,假一罚十。

    Q:下单后可以修改订单吗?
    A:下单后的商品付款之前可以修改;订单付款成功,需要联系我们客服进行修改;客服电话:4000-520-616

    Q:可以开发票吗?
    A:本网站所售商品都是正规清关,均开具16%正规发票,发票金额含配送费金额,另有说明的除外。

    Q:商品几天可以发货?
    A:生物188商品,全部现货销售,付款后即可发货,一般一周内送达!

    Q:如何联系商家?
    A:有任何问题够可以电话咨询我们,全国24小时免费服务热线:4000-520-616 或联系我们的在线客服QQ:1570468124

    Q:收到的商品少了/发错了怎么办?
    A:同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是 部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。

    Q:退换货/维修需要多长时间?
    A:一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、 数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。

何为188

极简而严谨,我们仅销售188款生物医学科研用品,款款都是爆款;因为少所以聚焦,聚焦甄选每一款产品,聚焦服务每一位客户!

关注我们 :

点击QQ联系我们
生物188微信

关注188微信公众号

获取最新优惠活动通知
  • 品质甄选,正品保证

  • 自营电商,厂家直采

  • 极简主义,188精品