Information Based on immunoelectrophoresis and/or ELISA, the antibody reacts with the Fc portion of human IgG heavy chain but not with the Fab portion of human IgG.No antibody was detected against human IgM or IgA, or against non-immunoglobulin serum proteins.The antibody may cross-react with immunoglobulins from other species.Fab fragment antibodies are generated by papain digestion of whole IgG antibodies to remove the entire Fc portion, including the hinge region. These antibodies are monovalent, containing only a single antigen binding site. The molecular weight of Fab fragments is about 50 kDa.
Usage Physical State: Freeze-dried solid Storage and Rehydration: Store freeze-dried solid at 2-8°C. Rehydrate with the indicated volume of dH2O (see product specification sheet) and centrifuge if not clear. Prepare working dilution on day of use. Product is stable for about 6 weeks at 2-8°C as an undiluted liquid.Extended Storage after Rehydration: Aliquot and freeze at -70°C or below. Avoid repeated freezing and thawing. Alternatively, add an equal volume of glycerol (ACS grade or better) for a final concentration of 50%, and store at -20°C as a liquid. Expiration date: one year from date of rehydration. The expiration date may be extended if test results are acceptable for the intended use.
Purity:The antibody was purified from antisera by a combination of papain digestion and immunoaffinity chromatography using antigens coupled to agarose beads.Fc fragments and whole IgG molecules have been removed. Buffer: 0.01M Sodium Phosphate, 0.25M NaCl, pH 7.6 Stabilizer:15 mg/ml Bovine Serum Albumin (IgG-Free, Protease-Free) Preservative:0.05% Sodium Azide Suggested Working Concentration or Dilution Range:1:100 - 1:800 for sequential labeling applications.
To complex with primary antibody in solution, use 1:1 weight ratio of Fab:primary antibody (3:1 molar ratio). Vortex and incubate for 30 minutes at room temperature prior to use. Titrate complex to optimal dilution for assay.
Dilution factors are presented in the form of a range because the optimal dilution is a function of many factors, such as antigen density, permeability, etc. The actual dilution used must be determined empirically.
Conjugate Cyanine Cy™3
Amax: 550Emax: 570nmCy3 is brighter, more photostable, and gives less background than other orange-red fluorescing dye conjugates. Cy3 conjugates can be excited maximally at 550 nm, with peak emission at 570 nm. For fluorescence microscopy, Cy3 can be visualized with traditional tetramethyl rhodamine (TRITC) filter sets, since the excitation and emission spectra are nearly identical to those of TRITC. We recommend Cy3 as a brighter alternative to TRITC. Cy3 can be excited to about 50% of maximum with an argon laser (514 nm or 528 nm lines), or to about 75% of maximum with a helium/neon laser (543 nm line) or mercury lamp (546 nm line). Cy3 has been used with fluorescein for double labeling; however, the use of a narrow band-pass emission filter for fluorescein is recommended to minimize Cy3 fluorescence in the FITC filter set. Cy3 can also be paired with Alexa Fluor® 647 for multiple labeling when using a confocal microscope. However, a better choice for multiple labeling is Rhodamine Red-X because its fluorescence is midway between a green fluorescing dye (like Alexa Fluor® 488) and a far-red-fluorescing dye like Alexa Fluor® 647.
Images & References
This product is for in vitro research use only. It is not a medical device and it is not intended for diagnostic or therapeutic purposes.
Cy is a trademark of GE Healthcare Bio-Sciences Ltd. Jackson ImmunoResearch is licensed by GE Healthcare Bio-Sciences Ltd. to manufacture and sell conjugates of Cy2, Cy3, and Cy5 reactive dyes under US Patent Number 5,268,486, and other patents pending.