Information Streptavidin, a bacterial protein isolated from Streptomyces avidinii, is similar to egg-white avidin in its ability to bind biotin, and has been used as a replacement for egg-white avidin because of its more favorable chemical properties.Conjugates of streptavidin are recommended for use with Biotin-SP-conjugated antibodies and Biotin-SP-conjugated ChromPure proteins.Usage Physical State: Freeze-dried solid Storage and Rehydration: Store freeze-dried solid at 2-8°C. Rehydrate with the indicated volume of dH2O (see product specification sheet) and centrifuge if not clear. Prepare working dilution on day of use. Product is stable for about 6 weeks at 2-8°C as an undiluted liquid.Extended Storage after Rehydration: Aliquot and freeze at -70°C or below. Avoid repeated freezing and thawing. Alternatively, add an equal volume of glycerol (ACS grade or better) for a final concentration of 50%, and store at -20°C as a liquid. Expiration date: one year from date of rehydration. The expiration date may be extended if test results are acceptable for the intended use.
Buffer: 0.01M Sodium Phosphate, 0.25M NaCl, pH 7.6 Stabilizer:15 mg/ml Bovine Serum Albumin (IgG-Free, Protease-Free) Preservative:0.05% Sodium Azide Suggested Working Concentration or Dilution Range:Western Blot:- 2-5 µg / mlHisto-/Cyto-Chemistry:-2-5 µg / mlDilution factors are presented in the form of a range because the optimal dilution is a function of many factors, such as antigen density, permeability, etc. The actual dilution used must be determined empirically.
Conjugate Cyanine Cy™2
Amax: 492Emax: 510nmCy2 conjugates have maximum absorption/excitation at 492 nm and fluoresce with a peak around 510 nm in the green region of the visible spectrum like FITC conjugates (520 nm), but they are more photostable and less sensitive to pH changes than FITC. However, for mounting in aqueous media we recommend Alexa Fluor® 488 as the preferred green-fluorescing dye because it is brighter and more photostable than Cy2, FITC, and DyLight 488. A further disadvantage of using Cy2 with aqueous mounting media is its sensitivity to p-phenylenediamine, an anti-fading agent found in some commercial mounting media, which results in weak and diffused fluorescence after storage of stained slides. The main advantage of Cy2 conjugates is increased fluorescence in plastic mounting media.
Images & References
This product is for in vitro research use only. It is not a medical device and it is not intended for diagnostic or therapeutic purposes.
Cy is a trademark of GE Healthcare Bio-Sciences Ltd. Jackson ImmunoResearch is licensed by GE Healthcare Bio-Sciences Ltd. to manufacture and sell conjugates of Cy2, Cy3, and Cy5 reactive dyes under US Patent Number 5,268,486, and other patents pending.